What power outages and surges do to dental office computers

Three kinds of power problems can affect your computers.

  • Surges and spikes are brief jumps in voltage. Some come from lightning or the utility; many start inside the building when large motors, such as an air compressor or vacuum system, switch on and off. A big surge can destroy a power supply; smaller ones wear electronics down over time.
  • Sags and brownouts are dips in voltage that can make computers freeze or restart without warning.
  • Outages cut power completely, from a brief flicker to hours. Anything without battery backup switches off.

The bigger risk is often your data. A computer that loses power while it is writing a file or database can leave it corrupted. That hurts most on the server, which in many offices holds the practice management database the whole team shares. A server that loses power suddenly can come back with a damaged database or disk, or not start at all.

Surge protectors vs. UPS battery backup

A surge protector diverts excess voltage away from your equipment, but does nothing when the power dips or fails. Its protective parts wear out as they absorb surges, so an old unit can keep passing power after it has stopped protecting anything. Many models have a light that shows whether protection is still active.

Not every power strip is a surge protector. Look for one listed as a surge protective device (in the US, UL 1449 on the label); a higher joule rating means it can absorb more energy before it wears out. Plug it straight into a grounded wall outlet, never into another strip.

A UPS (uninterruptible power supply) adds a battery. When the power fails or sags too far, the battery keeps your equipment running long enough to save work and shut down properly. Many UPS units include surge protection too.

Surge protector vs. UPS (battery backup) at a glance
QuestionSurge protectorUPS (battery backup)
Protects against surges and spikes?Yes, until its protective parts wear outYes, on many models
Keeps equipment on in an outage?NoYes, for a short time on battery
Handles sags and brownouts?NoYes, by correcting the voltage or switching to battery
Allows a safe shutdown?No, equipment switches off at onceYes, especially with shutdown software
UpkeepReplace when the protection light goes out or after a major surgeTest regularly and replace the battery every few years
Good fit forLaser printers and other equipment that can safely switch offThe server, network equipment and front desk PC

The three common types of UPS

The three main designs differ in how they handle normal power and how quickly they react to a problem.

Standby (offline)

Your equipment runs on filtered wall power, and the UPS switches to battery when the power fails or drifts out of range. The switch takes a moment, which desktop computers usually ride through. Standby units are simple and inexpensive, and suit a single workstation.

Line-interactive

A line-interactive UPS adds automatic voltage regulation, correcting sags and mild overvoltages without using the battery. It is a common choice for small servers and network equipment, especially where brownouts are frequent.

Online (double-conversion)

An online UPS converts incoming power to DC and back continuously, so your equipment always runs from its steady output with no switchover gap. It costs more and runs warmer and louder, and is usually chosen for servers that cannot tolerate any interruption.

Whatever the type, check that its battery output suits your equipment: many newer computers and servers run more reliably on a UPS with pure sine wave output.

What to plug into a UPS, and what to keep off it

Battery capacity is limited, so spend it on the equipment that matters in an outage:

  • The server, which holds the practice management and billing data everyone shares.
  • Network equipment: the modem, router or firewall and switches, so a flicker doesn’t drop every computer off the network.
  • The front desk PC and its monitor, so your team can close the practice software properly.
  • Other critical computers, such as the doctor’s office PC.

Keep laser printers off the battery outlets. They draw a burst of power when warming up that can overload a UPS, and many printer manufacturers advise against connecting them to one. Use a surge protector, or a UPS’s surge-only outlets, instead. Keep space heaters, refrigerators and other appliances off the UPS entirely.

Clinical equipment such as dental chairs and compressors has its own power requirements, so follow its manufacturer’s guidance rather than using a computer UPS.

What goes on battery backupIn short

  • The serverHolds the practice data everyone shares
  • Network equipmentModem, router or firewall and switches
  • Front desk PCSo the team can close software properly
  • Not laser printersSurge protector or surge-only outlets instead

Spend battery capacity on what matters in an outage

How much UPS runtime you need

A UPS isn’t meant to keep you working through a long outage. Its job is to ride out brief flickers and give your server and computers time to shut down safely when the power stays off.

A UPS carries two ratings, VA and watts. To size one, add up the watts drawn by everything on its battery outlets and keep the total well below the watt rating. Manufacturers publish runtime charts that show how long each model lasts at a given load. Leave headroom, because batteries lose capacity as they age.

Automatic safe-shutdown software

A UPS only buys time. If the power fails overnight or on a weekend, the battery runs down and the server crashes anyway, just a little later.

Shutdown software closes that gap. The UPS connects to the server by a USB or network cable, and software on the server watches the battery. After a set time on battery, or when the charge runs low, it closes programs and shuts the server down in an orderly way. Many setups can shut down other computers on the network too.

Test it by simulating an outage during a quiet time, as the UPS manual describes, and confirm the server shuts down cleanly. Decide, too, whether each machine should restart on its own when the power returns.

  1. Power fails
  2. Battery takes over
  3. Shutdown software
  4. Server shuts down safely

Automatic safe shutdownIn short

  • Connect the UPSBy USB or network cable to the server
  • Watch the batterySoftware tracks time on battery and charge left
  • Shut down in orderPrograms close before the battery runs out
  • Plan the restartDecide what restarts when the power returns

Testing and replacing UPS batteries

A UPS with a worn-out battery can look just like one that works, until the power fails. Build these checks into your routine.

  • Run the self-test regularly, and act on warning lights and beeps.
  • Replace the battery every few years, following the manufacturer’s guidance, or sooner if a test fails.
  • Label each UPS with the date its battery was installed.
  • Keep it cool and ventilated, since heat shortens battery life.
  • Replace surge protectors when the protection light goes out, or after a nearby lightning strike.

Surge protection for phone and network lines

A surge can also travel along the phone line, a cable internet connection or network cabling to reach your modem, router or computers.

Many surge protectors and UPS units have protected jacks for phone, coaxial or network cables, so route the incoming lines through them. Planning new lines? See our internet and phone line setup for dental offices.

Surge protectors also need properly grounded outlets to work as intended. A licensed electrician can check your wiring and advise on surge protection at the electrical panel.

A dental office power protection checklist

  • Server, network equipment and front desk PC on a UPS
  • Laser printers on a surge protector, not battery outlets
  • Shutdown software installed and tested
  • Enough runtime for a safe shutdown, with headroom
  • UPS batteries tested and replaced on time
  • Phone and internet lines surge protected
  • Outlets and grounding checked by an electrician
  • Current, tested backups of your practice data

Power protection limits damage, but it does not replace backups: a failed disk, ransomware or a burst pipe still calls for a safe copy of your data. Read our guide to dental office data backup and our guide to ransomware protection for dental offices.

Power planning also ties into the HIPAA Security Rule (45 CFR Part 164, Subpart C). Its contingency plan standard, 45 CFR 164.308(a)(7), calls for policies and procedures for responding to an emergency, such as a system failure, that damages systems containing electronic protected health information. It includes a data backup plan, a disaster recovery plan and an emergency mode operation plan. See our HIPAA Security Rule IT checklist.

How My Dental IT helps with power failures and surges

We handle disaster prevention and recovery in case of power failure or electrical surges, and set up backup systems and recovery software so vital data isn’t lost. See our dental data backup and recovery service.

We also install and maintain your desktops, tablet PCs and server systems, plus server monitoring software so problems are caught in an emergency.

This guide is general information, not legal advice.

Questions

Power outage and surge protection questions

Is a power strip the same as a surge protector?

No. A basic power strip only adds outlets, with no surge protection. A surge protector diverts excess voltage away from your equipment; in the US, check the label or packaging for a UL 1449 listing. Its protection wears down with use, and many models have an indicator light that tells you when it is time for a new one.

How long should a UPS keep our computers running?

Long enough to ride out short flickers and shut everything down safely, not to keep the office open for hours. Compare the load on the battery outlets with the manufacturer’s runtime chart, and allow for a battery that weakens with age. If your practice needs to keep working through long outages, ask a licensed electrician about a generator.

Does a UPS replace data backups?

No. A UPS helps prevent damage and corruption when the power fails, but it cannot help if a disk dies, ransomware strikes or the server is stolen. You still need tested backups of your practice data. Our dental office data backup guide explains what to protect, the 3-2-1 rule and how to test a restore.

Related

More ways to protect your practice data

All dental IT guides

Get your office ready for the next power outage

Tell us about your office, and we’ll talk you through protecting it from power failures and surges.